Principle of operation |
Magnetic Flux Leakage |
Detection |
18 off Hall Effect sensors |
Pipe diameters |
50 mm to 2.4 metre |
Method of propulsion |
Hand Push / Pull |
Speed |
0.5 m/sec |
Profile |
Clearance under / between pipework min 120 mm |
Thickness range |
Maximum 19 mm |
Test through coatings |
Yes if non magnetic |
Maximum coating thickness |
6 mm |
Sensitivity |
Adjustable |
Max sensitivity |
30% pitting in 6 mm wall pipe
40% pitting in 12 mm wall pipe
50% pitting in 19 mm wall pipe |
Connecting Cable |
5 metre standard length |
Power requirements |
12v battery operation |
Test Time |
10 hour continuous working |
Transit case |
Meets IATA requirements for transporting magnetizable material |
Operating weight |
18 Kg - combined weight of scanning head and electronics module |