| Principle of operation |
Magnetic Flux Leakage |
| Detection |
18 off Hall Effect sensors |
| Scan width |
150 mm |
| Method of propulsion |
Hand Push / Pull |
| Speed |
0.5 m/sec |
| Handle |
Extendable handle supplied |
| Profile |
Clearance under pipework required 120 mm |
| Thickness range |
Maximum 15 mm |
| Test through coatings |
Yes if non magnetic |
| Maximum coating thickness |
6 mm |
| Sensitivity |
adjustable |
| Max sensitivity |
10% underfloor on un-coated 6 mm plate
20% underfloor on coated 6 mm plate |
| Connecting Cable |
5 metre standard length |
| Power requirements |
12v battery operation |
| Test Time |
10 hour continuous working |
| Transit case |
Meets IATA requirements for transporting magnetizable
material |
| Operating weight |
18 Kg - combined weight of scanning head and electronics
module |