| Principle of operation |
Magnetic Flux Leakage |
| Detection |
32 off Hall Effect sensors |
| Scan width |
250mm |
| Maximum single scan length |
15 metres |
| Method of propulsion |
DC motor |
| Speed |
0.5m/ sec |
| Thickness range |
Maximum 10mm (automated sizing mode)
Maximum 20mm (detection mode only) |
| Test through coatings |
Yes if non magnetic |
| Maximum coating thickness |
6mm |
| Sensitivity |
adjustable |
| Max sensitivity |
20% underfloor corrosion |
| Autostop |
Yes (detection mode only) |
| Data storage |
Yes |
| Real time analysis |
Yes |
| Power requirements |
12v battery operation - 2 x 28 AHr batteries and 1 intelligent
charger allow continuous working |
| Transit case |
Meets IATA requirements for transporting magnetizable
material |
| Operating weight |
54 kg |